← All CVEs

CVE-2026-87663

HIGH 7.1

Published 2026-10-08 · Last modified 2026-10-09

An authentication bypass and command injection vulnerability exists in the inter-switch remote execution service of Brocade Fabric OS versions before 9.2.2d and 10.0.0 through 10.0.0a1. When processing remote command execution IPC frames across the fabric, the receiving switch processes these commands at an elevated processing level without proper verification of transmitted parameters. This allows an attacker on a single fabric-connected switch to escalate privileges and execute arbitrary root commands locally or across other managed fabric members where remote execution functionality is enabled.

ELEVATED IMPACT

Severe if exploited (CVSS 7.1), but no known exploitation and low modeled probability. Patch on a normal cadence.

Exploitation likelihood

0.7%chance of exploitation in 30 days · 51st percentile

○ In CISA KEV ○ Public exploit / PoC

Impact if exploited

7.1CVSS 4.0 · HIGH

  • ConfidentialityHigh
  • IntegrityHigh
  • AvailabilityHigh

What an attacker needs

  • ⚠Access: Requires local access to the host
  • ⚠Privileges: Requires an admin / high-privilege account
  • ✓User interaction: No user interaction needed
  • ✓Complexity: No special conditions — reliably repeatable
  • ⚠Requirements: Specific conditions must be present

✓ lowers the bar for an attacker · ⚠ raises it

Proof of concept & exploit code

Test against your own equipment

curl -s https://vulnpedia.com/cve/CVE-2026-87663/poc.jsonMachine-readable PoC index for this CVE (for automation).

Listed for defensive triage, patch verification, and authorized testing on systems you own. Machine-readable: /cve/CVE-2026-87663/poc.json

Affected

Vendors Brocade Broadcom

Products Fabric Os Fabric Operating System

Weakness (CWE)

  • CWE-290: : Authentication Bypass by Spoofing

CVSS vector

CVSS:4.0/AV:L/AC:L/AT:P/PR:H/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N

Known Affected Software Configurations

VendorProductVersion range
BroadcomFabric Operating System< 9.2.2d
BroadcomFabric Operating System≥ 10.0.0 and < 10.0.1

All CVSS metrics

  • HIGH 7.1 v4.0 · CNA Primary
    CVSS:4.0/AV:L/AC:L/AT:P/PR:H/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N
  • HIGH 7.1 v4.0 · NVD Secondary
    CVSS:4.0/AV:L/AC:L/AT:P/PR:H/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
  • MEDIUM 6.7 v3.1 · NVD Primary
    CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H

Sources: NVD · CVE.org · EPSS